{"id":16764,"date":"2019-04-25T16:12:06","date_gmt":"2019-04-25T15:12:06","guid":{"rendered":"https:\/\/www.buildingsmart.org\/?page_id=16764"},"modified":"2025-02-10T08:17:42","modified_gmt":"2025-02-10T08:17:42","slug":"standards-library","status":"publish","type":"page","link":"https:\/\/www.buildingsmart.org\/standards\/bsi-standards\/standards-library\/","title":{"rendered":"Standards Library"},"content":{"rendered":"\n\n\t<h1>Standards Library<\/h1>\n<nav aria-label=\"breadcrumbs\" class=\"rank-math-breadcrumb\"><p><span class=\"last\">Home<\/span><\/p><\/nav>\n\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--label-0\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-0\"><h3>buildingSMART International Standards<\/h3>These standards have been voted by the Standards Committee as being Final Standards.<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-0\" tabindex=\"-1\"><i title=\"Expand\">Expand<\/i><\/a>\n\t\t\t\t\t\n<table id=\"tablepress-1\" class=\"tablepress tablepress-id-1\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Title<\/th><th class=\"column-2\">Ref<\/th><th class=\"column-3\">Link<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">IFC ISO Standards<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/www.iso.org\/standard\/84123.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 16739-1<\/a><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">IFC Specifications<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/technical.buildingsmart.org\/standards\/ifc\/ifc-schema-specifications\/\" target=\"_blank\" rel=\"noopener noreferrer\">bSI Tech<\/a><\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">BIM Collaboration Format XML<\/td><td class=\"column-2\">S1005<\/td><td class=\"column-3\"><a href=\"https:\/\/github.com\/BuildingSMART\/BCF-XML\" target=\"_blank\" rel=\"noopener noreferrer\">BCF-XML<\/a><\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">BIM Collaboration Format API<\/td><td class=\"column-2\">S1006<\/td><td class=\"column-3\"><a href=\"https:\/\/github.com\/BuildingSMART\/BCF-API\" target=\"_blank\" rel=\"noopener noreferrer\">BCF-API<\/a><\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Foundation API<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/github.com\/buildingSMART\/foundation-api\" target=\"_blank\" rel=\"noopener noreferrer\">Foundation API<\/a><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Documents API<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/github.com\/buildingSMART\/documents-API\/\" target=\"_blank\" rel=\"noopener noreferrer\">Documents API<\/a><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">IFC4 Reference View<\/td><td class=\"column-2\">S1002<\/td><td class=\"column-3\"><a href=\"https:\/\/standards.buildingsmart.org\/MVD\/RELEASE\/IFC4\/ADD2_TC1\/RV1_2\/HTML\/\" target=\"_blank\" rel=\"noopener noreferrer\">Reference View 1.2<\/a><\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">IFC2x3 Coordination View<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/standards.buildingsmart.org\/MVD\/RELEASE\/IFC2x3\/TC1\/CV2_0\/IFC2x3_CV2_0.zip\" target=\"_blank\" rel=\"noopener noreferrer\">Coordination view 2.0<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-1 from cache -->\n\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--label-1\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-1\"><h3>buildingSMART Technical Reports<\/h3>A Technical Report encompasses a wide range of standards and services from buildingSMART, while also exploring opportunities for integration with other standards and domains.<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-1\" tabindex=\"-1\"><i title=\"Expand\">Expand<\/i><\/a>\n\t\t\t\t\t\n<table id=\"tablepress-2\" class=\"tablepress tablepress-id-2\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Title<\/th><th class=\"column-2\">Ref<\/th><th class=\"column-3\">Link<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">IFC Spatial Zone \u2013 Use Cases, Requirements and Implementation<\/td><td class=\"column-2\">BR-2023-1025-TR<\/td><td class=\"column-3\"><a href=\"https:\/\/app.box.com\/s\/t2m38rlfmpadw9sk2sq4z006nocl7hyt\" target=\"_blank\" rel=\"noopener noreferrer\">Report<\/a><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">BIM-BEM Workflows - an overview of requirements for developing IDMs between building information modelling and building energy modelling.<\/td><td class=\"column-2\">TR1044<\/td><td class=\"column-3\"><a href=\"https:\/\/app.box.com\/s\/1lo25g724749mbqjhgixy2nqdarq33uw\" target=\"_blank\" rel=\"noopener noreferrer\">Report<\/a><\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Nordic Study of Classification Systems for Infrastructure &amp; Transportation v1.0<\/td><td class=\"column-2\">IR-2020-1022-TR<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/08\/Nordic-Study-of-Classification-Systems-for-Infrastructure-Transportation-v1.0-1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Report<\/a><\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">e-submission common guidelines for introduce BIM to building process<\/td><td class=\"column-2\">RR-2020-1015-TR<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/08\/e-submission-guidelines-Published-Technical-Report-RR-2020-1015-TR-1.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Report<\/a><\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Application forms: Common information requirements for automated compliance checking<\/td><td class=\"column-2\">TR 1013<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/07\/buildingSMART-RR-Forms-TR13-Final-Aug-2019.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Report<\/a><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Beyond e-permitting: Framing the Business Case for Automated Rule Checking in AEC in the Era of Big Data<\/td><td class=\"column-2\">TR-2020-1016-RR<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/06\/buildingSMART-RR-TR1012-Framing-the-Business-Case-for-Automated-Rule-Checking-v1.1-Final-Dec-2019.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Report<\/a><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Built environment data standards and their integration: an analysis of IFC, CityGML and LandInfra<\/td><td class=\"column-2\">TR1012<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2021\/02\/IDBE_Standards_Integration_v1.1_28_JAN_2021.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Report<\/a><\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">IFC Infra Overall Architecture<\/td><td class=\"column-2\">TR1009<\/td><td class=\"column-3\"><a href=\"http:\/\/buildingsmart.org\/wp-content\/uploads\/2017\/07\/08_bSI_OverallArchitecure_Guidelines_final.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Report<\/a><\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Open Standards for Regulation<\/td><td class=\"column-2\">TR1011<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2017\/11\/17-11-08-Open-Standards-for-Regulation.pdf\" target=\"_blank\" rel=\"noopener\">Regulatory report<\/a><\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Infra Asset Management<\/td><td class=\"column-2\">TR1010<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2018\/01\/18-01-09-AM-TR1010.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Asset Management<\/a><\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">User Guide for Geo-referencing in IFC<\/td><td class=\"column-2\">v2.0 Jan 2020<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/02\/User-Guide-for-Geo-referencing-in-IFC-v2.0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">User Guide<\/a><br \/>\n<a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/02\/Executive-Summary-User-Guide-for-Geo-referencing-in-IFC-v2.0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Executive Summary <\/a><br \/>\n<a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/02\/Appendix-A-Demonstration-Scenario-for-Model-Setup-IDM-v2.0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Appendix A <\/a>, <a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/02\/Appendix-B-Geo-referencing-BIM-v2.0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Appendix B <\/a>, <a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/02\/Appendix-C-Process-Model-v2.0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Appendix C <\/a>, <a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/02\/Appendix-D-MSI-Exchange-Requirements-v2.0.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Appendix D<\/a>.<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-2 from cache -->\n\n<table id=\"tablepress-1-no-2\" class=\"tablepress tablepress-id-1\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Title<\/th><th class=\"column-2\">Ref<\/th><th class=\"column-3\">Link<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">IFC ISO Standards<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/www.iso.org\/standard\/84123.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO 16739-1<\/a><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">IFC Specifications<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/technical.buildingsmart.org\/standards\/ifc\/ifc-schema-specifications\/\" target=\"_blank\" rel=\"noopener noreferrer\">bSI Tech<\/a><\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">BIM Collaboration Format XML<\/td><td class=\"column-2\">S1005<\/td><td class=\"column-3\"><a href=\"https:\/\/github.com\/BuildingSMART\/BCF-XML\" target=\"_blank\" rel=\"noopener noreferrer\">BCF-XML<\/a><\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">BIM Collaboration Format API<\/td><td class=\"column-2\">S1006<\/td><td class=\"column-3\"><a href=\"https:\/\/github.com\/BuildingSMART\/BCF-API\" target=\"_blank\" rel=\"noopener noreferrer\">BCF-API<\/a><\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Foundation API<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/github.com\/buildingSMART\/foundation-api\" target=\"_blank\" rel=\"noopener noreferrer\">Foundation API<\/a><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Documents API<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/github.com\/buildingSMART\/documents-API\/\" target=\"_blank\" rel=\"noopener noreferrer\">Documents API<\/a><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">IFC4 Reference View<\/td><td class=\"column-2\">S1002<\/td><td class=\"column-3\"><a href=\"https:\/\/standards.buildingsmart.org\/MVD\/RELEASE\/IFC4\/ADD2_TC1\/RV1_2\/HTML\/\" target=\"_blank\" rel=\"noopener noreferrer\">Reference View 1.2<\/a><\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">IFC2x3 Coordination View<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/standards.buildingsmart.org\/MVD\/RELEASE\/IFC2x3\/TC1\/CV2_0\/IFC2x3_CV2_0.zip\" target=\"_blank\" rel=\"noopener noreferrer\">Coordination view 2.0<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-1-no-2 from cache -->\n\n<table id=\"tablepress-46\" class=\"tablepress tablepress-id-46\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Title<\/th><th class=\"column-2\">Ref<\/th><th class=\"column-3\">Approved by:<\/th><th class=\"column-4\">Link<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">IFC4Precast IDM<\/td><td class=\"column-2\">BR-2020-1023-CS<\/td><td class=\"column-3\">building Room, bSI  Standards Committee<\/td><td class=\"column-4\"><a href=\"https:\/\/app.box.com\/s\/knvbdnufdckvkeaslyh194gnu6a2c5pz\" target=\"_blank\" rel=\"noopener noreferrer\">IFC4 Precast IDM<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-46 from cache -->\n<p>Since early 2022, standards coming from the buildingSMART Rooms are published in the Use-Case Management Service that can be found on https:\/\/ucm.buildingsmart.org\/<\/p>\n\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--label-2\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-2\"><h3>Industry Foundation Classes Policies<\/h3>Policies regarding Industry Foundation Classes (IFC) cover usage, guidelines and deployment by the industry.<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-2\" tabindex=\"-1\"><i title=\"Expand\">Expand<\/i><\/a>\n\t\t\t\t\t\n<table id=\"tablepress-43\" class=\"tablepress tablepress-id-43\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Title<\/th><th class=\"column-2\">Ref<\/th><th class=\"column-3\">Link<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">IFC 4.x MVD Policy<\/td><td class=\"column-2\">MO-2021-2<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2021\/05\/20210425_MVD-policy_IFC4.x.pdf\" target=\"_blank\" rel=\"noopener\">IFC 4.x MVD Policy<\/a><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">IFC 4.3.x Deployment Guidelines<\/td><td class=\"column-2\">MO-2021-1<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2021\/02\/20210201_ifc4.3.x_deployment_guidelines.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">IFC 4.3.x Delivery &amp; Deployment guidelines<\/a><\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">IFC bSDD Policy Statement<\/td><td class=\"column-2\">MO-2020<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2021\/03\/20200227_IFC-bSDD_Policy-Statement.pdf\" target=\"_blank\" rel=\"noopener\">IFC and bSDD Relation Policy<\/a><\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Future of the Industry Foundation Classes: towards IFC 5<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2021\/06\/IFC_5.pdf\" target=\"_blank\" rel=\"noopener\">Progress Report<\/a><br \/>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-43 from cache -->\n\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--label-3\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-3\"><h3>buildingSMART Candidate Standards<\/h3>Candidate standards are activities that are in the process of acquiring international consensus before being submitted to the Standards Committee for the final vote.<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-3\" tabindex=\"-1\"><i title=\"Expand\">Expand<\/i><\/a>\n\t\t\t\t\t\n<table id=\"tablepress-3\" class=\"tablepress tablepress-id-3\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Title<\/th><th class=\"column-2\">Ref<\/th><th class=\"column-3\">Link<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Information Delivery Specification (IDS)<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/github.com\/buildingSMART\/IDS\" target=\"_blank\" rel=\"noopener noreferrer\">Information Delivery Specification (IDS)<\/a><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Quantity Take-Off<br \/>\nInformation Delivery Manual<\/td><td class=\"column-2\">BR-2025-1024-CS<\/td><td class=\"column-3\"><a href=\"https:\/\/app.box.com\/s\/k6gsocsfsco6j9luazo9jn1o63wct1da\" target=\"_blank\" rel=\"noopener noreferrer\">Information here<\/a><\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">IFC Rail Project - Abstract<\/td><td class=\"column-2\">P26<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2019\/10\/RWR-IFC_Rail_Abstract_.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Information here<\/a><\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">IFC Rail Project - Conceptual Model Report<\/td><td class=\"column-2\">P26<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2019\/10\/RWR-IFC_Rail-Conceptual_Model_Report_.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Information here<\/a><\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">IFC Rail Project  - Context &amp; Approach<\/td><td class=\"column-2\">P26<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/06\/RWR-IFC_Rail-Context-Approach.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Information here<\/a><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">IFC Rail Project - Data Requirement Report<\/td><td class=\"column-2\">P26<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2019\/10\/RWR-IFC_Rail-Data_Requirements_Report_-_.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Information here<\/a><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">IFC Rail Project - Requirement Analysis Report<\/td><td class=\"column-2\">P26<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2019\/10\/RWR-IFC_Rail-Requirement_Analysis_Report_-_.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Information here<\/a><\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">UML Model Report \u2013 Part 1: Introduction to the IFC Harmonised Schema Extensions<\/td><td class=\"column-2\">TR-2020-1019-IRa<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/06\/IR-CS-WP2-UML_Model_Report_Part-1_.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Information here<\/a><\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">UML Model Report \u2013 Part 2: Common Schema Elements<\/td><td class=\"column-2\">TR-2020-1019-IRb<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/06\/IR-CS-WP2-UML_Model_Report_Part-2_.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Information here<\/a><\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">UML Model Report \u2013 Part 3: Ports and Waterways Elements<\/td><td class=\"column-2\">TR-2020-1019-IRc<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/06\/IR-CS-WP2-UML_Model_Report_Part-3_.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Information here<\/a><\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">UML Model Report \u2013 Part 4: Railway Schema Elements<\/td><td class=\"column-2\">TR-2020-1019-IRd<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/06\/IR-CS-WP2-UML_Model_Report_Part-4_.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Information here<\/a><\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">UML Model Report \u2013 Part 5: Road Schema Elements<\/td><td class=\"column-2\">TR-2020-1019-IRe<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2020\/06\/IR-CS-WP2-UML_Model_Report_Part-5_.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">Information here<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-3 from cache -->\n\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--label-4\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-4\"><h3>buildingSMART SPEC<\/h3>buildingSMART SPEC is a document that can be produced by any organisation that wants to standardize best practice on a specific subject but is not yet ready to proceed with producing it as a bSI Standard.  It is a publicly available specification.<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-4\" tabindex=\"-1\"><i title=\"Expand\">Expand<\/i><\/a>\n\t\t\t\t\t\n<table id=\"tablepress-4\" class=\"tablepress tablepress-id-4\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Title<\/th><th class=\"column-2\">Organisation<\/th><th class=\"column-3\">Link<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">IFC Rail bSI SPEC<\/td><td class=\"column-2\">China Rail BIM Alliance<\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2017\/09\/bSI-SPEC-Rail.pdf\" target=\"_blank\">bSI SPEC Rail part 1<\/a><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2017\/09\/bSI-SPEC-Rail-part-2.pdf\" target=\"_blank\">bSI SPEC Rail part 2<\/a><\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">IFC Road bSI SPEC<\/td><td class=\"column-2\"> Korean Institute Construction Technology<\/td><td class=\"column-3\">See below<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-4 from cache -->\n\n<table id=\"tablepress-30\" class=\"tablepress tablepress-id-30\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Content\/Chapter<\/th><th class=\"column-2\">Title<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2017\/07\/Contents.pdf\" rel=\"noopener\" target=\"_blank\">Contents<\/a><\/td><td class=\"column-2\"><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2017\/07\/Chapts-1-2c.pdf\" rel=\"noopener\" target=\"_blank\">Chapters 1 \u2013 2<\/a><\/td><td class=\"column-2\">Schedule and Development History<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2017\/07\/Chapts-3c.pdf\" rel=\"noopener\" target=\"_blank\">Chapter 3<\/a><\/td><td class=\"column-2\">Infra IFC Schema (Express-G) V1.0<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2017\/07\/Chapts-4-5c.pdf\" rel=\"noopener\" target=\"_blank\">Chapters 4 \u2013 5<\/a><\/td><td class=\"column-2\">Infra IFC Entities including IfcRoad <\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2017\/07\/Chapts-6-8c.pdf\" rel=\"noopener\" target=\"_blank\">Chapters 6 \u2013 8<\/a><\/td><td class=\"column-2\">Property Sets for IfcRoad V1.0 <\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\"><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2017\/07\/Chapt-9c.pdf\" rel=\"noopener\" target=\"_blank\">Chapter 9<\/a><\/td><td class=\"column-2\">Infra IFC Specifications with IfcRoad V0.6<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-30 from cache -->\n\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--label-5\" tabindex=\"0\" aria-controls=\"fl-accordion--panel-5\"><h3>National and Local buildingSMART Reports<\/h3>Discover national and local buildingSMART standards and services through these comprehensive reports. They feature domain-specific content, technical specifications, and additional insights.<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"#\" id=\"fl-accordion--icon-5\" tabindex=\"-1\"><i title=\"Expand\">Expand<\/i><\/a>\n\t\t\t\t\t\n<table id=\"tablepress-8\" class=\"tablepress tablepress-id-8\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">bSI Relationship<\/th><th class=\"column-2\">Publisher<\/th><th class=\"column-3\">Content<\/th><th class=\"column-4\">Link<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">MVD Database<\/td><td class=\"column-2\">divers<\/td><td class=\"column-3\">MVDs<\/td><td class=\"column-4\"><a href=\"https:\/\/technical.buildingsmart.org\/standards\/ifc\/mvd\/mvd-database\/\" target=\"_blank\" rel=\"noopener noreferrer\">MVD Database<\/a><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">buildingSMART National Standards<\/td><td class=\"column-2\">USA<\/td><td class=\"column-3\">US COBie Version 2.4<\/td><td class=\"column-4\"><a href=\"https:\/\/www.wbdg.org\/bim\/cobie\" target=\"_blank\" rel=\"noopener noreferrer\">COBie<\/a><\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">buildingSMART National Standards<\/td><td class=\"column-2\">USA<\/td><td class=\"column-3\">US HVCAie<\/td><td class=\"column-4\"><a href=\"http:\/\/docs.buildingsmartalliance.org\/MVD_HVACIE\/\" target=\"_blank\" rel=\"noopener noreferrer\">bSA<\/a><\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">buildingSMART National Standards<\/td><td class=\"column-2\">USA<\/td><td class=\"column-3\">US SPARKie<\/td><td class=\"column-4\"><a href=\"http:\/\/docs.buildingsmartalliance.org\/MVD_SPARKIE\/\" target=\"_blank\" rel=\"noopener noreferrer\">bSA<\/a><\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">buildingSMART National Standards<\/td><td class=\"column-2\">USA<\/td><td class=\"column-3\">US WSie<\/td><td class=\"column-4\"><a href=\"http:\/\/docs.buildingsmartalliance.org\/MVD_WSIE\/\" target=\"_blank\" rel=\"noopener noreferrer\">bSA<\/a><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">IFC Based<\/td><td class=\"column-2\">ISO<\/td><td class=\"column-3\">ISO 19650<\/td><td class=\"column-4\"><a href=\"https:\/\/www.iso.org\/standard\/68078.html\" target=\"_blank\" rel=\"noopener noreferrer\">ISO<\/a><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">IFC Based<\/td><td class=\"column-2\">Auckland University<\/td><td class=\"column-3\">Content Models<\/td><td class=\"column-4\"><a href=\"http:\/\/openifcmodel.cs.auckland.ac.nz\/\" target=\"_blank\" rel=\"noopener noreferrer\">Auckland University<\/a><\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">IFC Based<\/td><td class=\"column-2\">Pankow Foundation<\/td><td class=\"column-3\">US BIM Standard for Precast Concrete<\/td><td class=\"column-4\"><a href=\"https:\/\/jaguar-olive-k9tx.squarespace.com\/our-work\" target=\"_blank\" rel=\"noopener noreferrer\">Pankow Foundation<\/a><\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">IFC Based<\/td><td class=\"column-2\">Pankow Foundation<\/td><td class=\"column-3\">US Owner's Guide to BIM<\/td><td class=\"column-4\"><a href=\"https:\/\/jaguar-olive-k9tx.squarespace.com\/our-work\" target=\"_blank\" rel=\"noopener noreferrer\">Pankow Foundation<\/a><\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">IFC Based<\/td><td class=\"column-2\">American Institute of Steel Construction<\/td><td class=\"column-3\">BIM steel initiatives<\/td><td class=\"column-4\"><a href=\"https:\/\/www.aisc.org\/why-steel\/resources\/bim\/\" target=\"_blank\" rel=\"noopener noreferrer\">AISC<\/a><\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">BIM Qualification <\/td><td class=\"column-2\">VDI<\/td><td class=\"column-3\">Basic Knowledge VDI\/bS 2552 Sheet 8.1<\/td><td class=\"column-4\"><a href=\"https:\/\/www.vdi.de\/richtlinien\/seite?tx_vdiguidelines_guidelinelist%5Bfilter%5D%5BsearchTerm%5D=2552&amp;cHash=f4723696fdc8149df978e1c99bb434f0#richtlinien\" target=\"_blank\" rel=\"noopener noreferrer\">Read More<\/a><\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">BIM Qualification <\/td><td class=\"column-2\">VDI<\/td><td class=\"column-3\">Advanced Knowledge VDI\/bS 2552 Sheet 8.2<\/td><td class=\"column-4\"><a href=\"https:\/\/www.vdi.de\/richtlinien\/seite?tx_vdiguidelines_guidelinelist%5Bfilter%5D%5BsearchTerm%5D=2552&amp;cHash=f4723696fdc8149df978e1c99bb434f0#richtlinien\" target=\"_blank\" rel=\"noopener noreferrer\">Read More<\/a><\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">BIM Information Delivery<\/td><td class=\"column-2\">VDI<\/td><td class=\"column-3\">Information Exchange Requirements Methodology VDI\/bS 2552 Sheet 11.1<\/td><td class=\"column-4\"><a href=\"https:\/\/www.vdi.de\/richtlinien\/seite?tx_vdiguidelines_guidelinelist%5Bfilter%5D%5BsearchTerm%5D=2552&amp;cHash=f4723696fdc8149df978e1c99bb434f0#richtlinien\" target=\"_blank\" rel=\"noopener noreferrer\">Read More<\/a><\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">BIM Information Delivery<\/td><td class=\"column-2\">VDI<\/td><td class=\"column-3\">IER Slot and Breakthrough Coordination VDI\/bS 2552 Sheet 11.2<\/td><td class=\"column-4\"><a href=\"https:\/\/www.vdi.de\/richtlinien\/seite?tx_vdiguidelines_guidelinelist%5Bfilter%5D%5BsearchTerm%5D=2552&amp;cHash=f4723696fdc8149df978e1c99bb434f0#richtlinien\" target=\"_blank\" rel=\"noopener noreferrer\">Read More<\/a><\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">BIM Information Delivery<\/td><td class=\"column-2\">VDI<\/td><td class=\"column-3\">IER Formwork and Scaffolding Design VDI\/bS 2552 Sheet 11.3<\/td><td class=\"column-4\"><a href=\"https:\/\/www.vdi.de\/richtlinien\/seite?tx_vdiguidelines_guidelinelist%5Bfilter%5D%5BsearchTerm%5D=2552&amp;cHash=f4723696fdc8149df978e1c99bb434f0#richtlinien\" target=\"_blank\" rel=\"noopener noreferrer\">Read More<\/a><\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">BIM Information Delivery<\/td><td class=\"column-2\">VDI<\/td><td class=\"column-3\">IER Lifecycle Assessment VDI\/bS 2552 Sheet 11.4<\/td><td class=\"column-4\"><a href=\"https:\/\/www.vdi.de\/richtlinien\/seite?tx_vdiguidelines_guidelinelist%5Bfilter%5D%5BsearchTerm%5D=2552&amp;cHash=f4723696fdc8149df978e1c99bb434f0#richtlinien\" target=\"_blank\" rel=\"noopener noreferrer\">Read More<\/a><\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">BIM Information Delivery<\/td><td class=\"column-2\">VDI<\/td><td class=\"column-3\">IER Elevator Planning VDI\/bS 2552 Sheet 11.5<\/td><td class=\"column-4\"><a href=\"https:\/\/www.vdi.de\/richtlinien\/seite?tx_vdiguidelines_guidelinelist%5Bfilter%5D%5BsearchTerm%5D=2552&amp;cHash=f4723696fdc8149df978e1c99bb434f0#richtlinien\" target=\"_blank\" rel=\"noopener noreferrer\">Read More<\/a><\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">BIM Information Delivery<\/td><td class=\"column-2\">VDI<\/td><td class=\"column-3\">IER Fire Protection VDI\/bS 2552 Sheet 11.6<\/td><td class=\"column-4\"><a href=\"https:\/\/www.vdi.de\/richtlinien\/seite?tx_vdiguidelines_guidelinelist%5Bfilter%5D%5BsearchTerm%5D=2552&amp;cHash=f4723696fdc8149df978e1c99bb434f0#richtlinien\" target=\"_blank\" rel=\"noopener noreferrer\">Read More<\/a><\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">BIM Information Delivery<\/td><td class=\"column-2\">VDI<\/td><td class=\"column-3\">IER Doors VDI\/bS 2552 Sheet 11.6<\/td><td class=\"column-4\"><a href=\"https:\/\/www.vdi.de\/richtlinien\/seite?tx_vdiguidelines_guidelinelist%5Bfilter%5D%5BsearchTerm%5D=2552&amp;cHash=f4723696fdc8149df978e1c99bb434f0#richtlinien\" target=\"_blank\" rel=\"noopener noreferrer\">Read More<\/a><\/td>\n<\/tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">BIM Information Delivery<\/td><td class=\"column-2\">VDI<\/td><td class=\"column-3\">IER Factory Planning VDI\/bS 2552 Sheet 11.7<\/td><td class=\"column-4\"><a href=\"https:\/\/www.vdi.de\/richtlinien\/seite?tx_vdiguidelines_guidelinelist%5Bfilter%5D%5BsearchTerm%5D=2552&amp;cHash=f4723696fdc8149df978e1c99bb434f0#richtlinien\" target=\"_blank\" rel=\"noopener noreferrer\">Read More<\/a><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-8 from cache -->\n<p>* BSI (British Standards Institution)<\/p>\n<p>If you publish an open IFC library and would like us to link to your site then please <a href=\"https:\/\/www.buildingsmart.org\/contact-us\/\" target=\"_blank\" rel=\"noopener\">contact us<\/a>.<\/p>\n\t<p><a href=\"https:\/\/www.buildingsmart.org\/wp-content\/uploads\/2022\/03\/Copyright-Notice-8-Mar-22.pdf\" target=\"_blank\" rel=\"noopener\">Copyright Notice<\/a><\/p>\n<h2>\n\t\tGet Involved Today\n\t<\/h2>\n\t<p>Participate in buildingSMART work on the new standards for the industry.<\/p>\n\n","protected":false},"excerpt":{"rendered":"<p>Standards Library buildingSMART International Standards These standards have been voted by the Standards Committee as being Final Standards. Expand buildingSMART Technical Reports A Technical Report encompasses a wide range of&hellip;<\/p>\n","protected":false},"author":5,"featured_media":0,"parent":16759,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":"","_links_to":"","_links_to_target":""},"class_list":["post-16764","page","type-page","status-publish","hentry"],"wpsp_post_type":null,"_links":{"self":[{"href":"https:\/\/www.buildingsmart.org\/wp-json\/wp\/v2\/pages\/16764","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.buildingsmart.org\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.buildingsmart.org\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.buildingsmart.org\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/www.buildingsmart.org\/wp-json\/wp\/v2\/comments?post=16764"}],"version-history":[{"count":0,"href":"https:\/\/www.buildingsmart.org\/wp-json\/wp\/v2\/pages\/16764\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.buildingsmart.org\/wp-json\/wp\/v2\/pages\/16759"}],"wp:attachment":[{"href":"https:\/\/www.buildingsmart.org\/wp-json\/wp\/v2\/media?parent=16764"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}